UPS+ESS UE3020 / UE3030
Commercial application
Provide medical equipment for long-term care centers, store freezers, engine rooms... uninterruptible power supply.
UPS + ESS
This model provides 2KW~3KW optional.
When the mains power fails to provide normal power, has a power outage or power outage, the product can instantly supply power to ensure stable and continuous power supply for the equipment.
Our company's UPS system is combined with the ESS energy storage system and uses lithium-ion ternary batteries. The lithium-ion batteries maintain stable power supply for a long time, and the output voltage is a pure sine wave, which can provide better power quality for the equipment.
lithium-ion batteries are not only charged through mains power, but also provide green energy and environmentally friendly charging through solar charging systems, achieving endless power and sharing the consumption and electricity bills of mains power.
It can be used for medical long-term care equipment, school equipment, emergency equipment, office equipment, home power supply, and business backup power supply.
Model | UE3020 / UE3030 | UE5050 / UE5070 | ||
Charger | Built-in A C & PV charger. | |||
Power output | 3KW; 110/120Vac | 5KW; 220/230Vac | ||
Battery capacity | 2KWh / 3KWh | 5KWh / 7KWh | ||
Dimension (WxLxH)mm | 205 (W) x 480 (L) x 435 (H) mm | 308 (W) x 520 (L) x 435 (H) mm | ||
Weight | 25Kg / 30Kg | 47Kg / 55Kg | ||
Battery voltage/current | 50.4V/40A | 50.4V/130A | ||
Battery capacity | 2000 Wh/ 3000 Wh | 5000 Wh/ 7000 Wh | ||
Function | AC output *4、Interface display、Double heat dissipation hole design、PV IN、AC Input *1 | |||
Mains power input specifications | ||||
Rated input voltage | 110/120Vac | 220/230Vac | ||
Input voltage range | 90Vac ~ 140Vac ± 2% | 170Vac ~ 280Vac ± 2% | ||
Rated input current | 15A | 25A | ||
Please confirm that the socket capacity meets the above current amount to ensure safe use of electricity! | ||||
Frequency | 50Hz / 60Hz (Automatic detection) | |||
Frequency range | 50Hz: 47 ±0.3Hz ~ 55±0.3Hz; 60Hz: 57±0.3Hz ~ 65±0.3Hz | |||
Overload/Short circuit protection | Breaker | |||
Efficiency | > 95% | |||
Conversion time (bypass and inverter) | 10ms (Typical value) | |||
AC backfeed protection | Available | |||
Max. bypass overload current | 40A | |||
Inverter specifications | ||||
Output voltage waveform | Pure sine wave | |||
Rated output power (VA) | 3000 | 5000 | ||
Rated output power (W) | 3000 | 5000 | ||
Power factor | 1 | |||
Rated output voltage (VAC) | 120Vac | 230Vac | ||
Output voltage error | ± 5% | |||
Output frequency range (Hz) | 50 Hz ± 0.3Hz;60Hz ± 0.3Hz | |||
Efficiency | > 90% | |||
Overload protection | (102% < Load < 110%) ±10%: Turn off the output after 5 minutes of alarm; (110% < Load < 125%) ±10%: Turn off the output after 10 seconds of alarm; Load>125% ±10%: Turn off the output after 5 seconds of alarm |
(102% < Load < 125%) ±10%: Turn off the output after 5 minutes of alarm; (110% < Load < 150%) ±10%: Turn off the output after 10 seconds of alarm; Load>150% ±10%: Turn off the output after 5 seconds of alarm |
||
Peak power | 6000VA | 10000VA | ||
Load motor capacity | 1HP | 4HP | ||
Output short circuit protection | Breaker | |||
Bypass circuit breaker specifications | 40A | |||
Rated battery input voltage | 48V (Minimum starting voltage 44V) | |||
Battery voltage range | 40.0Vdc~60Vdc±0.6Vdc (Low voltage alarm / Low voltage protection / Over voltage alarm / Over voltage recovery...LCD screen can be set.) |
|||
Power saving mode | Load ≦ 25W | |||
Solar charging specifications | ||||
Max. PV cross-circuit voltage | 145Vdc | |||
PV operating voltage range | 60-145Vdc | |||
MPPT voltage range | 60-115Vdc | |||
Battery voltage range | 40-60Vdc | |||
Max. output power | 3200W | 4200W | ||
Solar charging current range (can be set) |
0-60A | 0-80A | ||
Charging short circuit protection | Blown fuse | |||
Wiring protection | Reverse connection protection | |||
Certification specifications | ||||
Certification specifications | CE(EN62040-1) | |||
EMC certification level | EN62040-2,C2 | |||
Range of working temperature | -15 ℃ ~ 55℃ | |||
Storage temperature range | -25 ℃ ~ 60℃ | |||
Humidity range | 5% ~ 95% (Three-proof paint protection) | |||
Noise | ≦ 60dB | |||
Heat dissipation | Forced air cooling, adjustable wind speed. | |||
Communication interface (optional function) | USB / RS485(Bluetooth/WiFi/GPRS) / Dry contact control | |||
Battery cell specifications | ||||
Battery type | LG 21700 Ternary Lithium. | |||
Max. charging current | 20A | 40A | ||
Charging current error | ± 5Adc | |||
Charging voltage range | 58Vdc | |||
Short circuit protection | Circuit breakers and blown fuses. | |||
Circuit breaker specifications | 40A | |||
Over charge protection | Turn off charging after 1 minute of warning. | |||
Reference for power supply time when the battery is fully charged. | ||||
Product | Wattage consumed | Usage time(hr) | Wattage consumed | Usage time(hr) |
Electric fan | 100 | 16 / 24 | - | - |
Hair dryer | 1500 | 1.1 / 1.6 | - | - |
Datong electric cooker | 700 | 2.3 / 3.4 | - | - |
250L refrigerator | 100 | 16 / 24 | - | - |
Inverter air conditioner | 900 | 1.8 / 2.6 | - | - |
1KL inverter refrigerator for business use | - | - | 960 | 4.1 / 5.8 |
40L electric oven | - | - | 1500 | 2.6 / 3.7 |
LED outdoor lighting | - | - | 200 | 20 / 28 |
29.754-36.366 sqm. separated air conditioner | - | - | 1800 | 2.2 / 3.1 |